Book type EMI filters
Mains voltage
3 x 480 VAC
Rated current
7 A … 130 A
Frequency
upto60Hz
Operating and storage temperature
-25°C...+80°C(climateclassacc.toCEI25/80/21)
Type of protection
IP20
Maximum length of motor cables:
ACU 401-01 to -15: 25 m class B
ACU 401-18 to -25: 50 m class B
ACU 401-27 to -39: 10 m class B, 100 m class A group 1
ACU 401-43 to -49: 10 m class B, 100 m class A group 1
Note
Overload capacity is 4 times rated current at switch-
on; 1.5 times rated current for 1 minute, once per
hour.
Bonfiglioli Inverter
Bonfiglioli
EMI filter
Rated
current
Leakage
current
Power
dissipation
Weight
Size Type [A] [mA] [W] [kg]
1
ACU 201-01
FTV007A 7
33
3.8 0.5
ACU 201-03
ACU 201-05
ACU 201-07
ACU 201-09
ACU 401-01
ACU 401-03
ACU 401-05
ACU 401-07
ACU 401-09
ACU 401-11
2
ACU 201-11
ACU 401-12
ACU 401-13
ACU 401-15
ACU 201-13
FTV016A 16 6.1 0.8
ACU 201-15
ACU 401-18
3
ACU 401-19
ACU 401-21
ACU 201-18
FTV030A 30 11.8 1.2
ACU 201-19
ACU 401-22
4
ACU 201-21
ACU 401-23
ACU 401-25
ACU 201-22
FTV055A 55 25.9 2.0
5
ACU 401-27
ACU 401-29
ACU 401-31 FTV075A 75 32.2 2.7
6
ACU 401-33
FTV100A 100 34.5 4.3
ACU 401-35
ACU 401-37
FTV130A 130 43.1 4.5
ACU 401-39
7
ACU 401-43
FTV180A 180 33 58.3 6.0
ACU 401-45
ACU 401-47
FTV250A 250 98 90 12.4
ACU 401-49