15
1
ACU201- 01 03 05 07 09 11 13 15
Size 1 (F, A) Size 2 (F, A)
Output, motor side
Rated motor current output I
n
A 1.6 2.5 3.0 4.0 5.5 7.0 9.5 12.5
Rated motor voltage output U
n
V 3 x (from 0 to mains voltage)
Overload current I
pk
A 3.2 5.0 4.5 6.0 7.3 10.5 14.3 16.2
Recommended rated motor power P
n
kW 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0
Switching frequency f
c
kHz From 2 to 6
Rated motor frequency f
n
Hz From 0 to 1000
Input, mains side
Rated mains voltage U V 184 ... 264
Rated mains frequency F Hz 45 ... 66
Rated current 3 ph/PE I A 1.6 2.5 3.0 4.0 5.5 7.0 9.5 10.5
Rated current 1 ph/N/PE; 2 ph/PE I A 2.9 4.5 5.4 7.2 9.5 13.2 16.5 16.5
General
Short circuit / ground fault protection - - Yes, unlimited
Mounting position - - Vertical
Protection class - - IP 20 (EN60529)
Dimensions Std. A
HxWxD
mm 190 x 60 x 175 250 x 60 x 175
Weight (approx.) m kg 1.2 1.6
Brake unit - - Internal brake transistor
Environment
Cooling temperature T
n
°C From0to40(3K3DINIEC721-3-3)
Relative air humidity - % From 15 to 85, non-condensing
Options & accessories
Input line choke - - External (depending on mains supply)
EMI filter - - Internal Class A (EN 61800-3); external Class B
Digital control unit - - yes