BONFIGLIOLI act 401 Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 74
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
14
ACT201 - Technical data (from 0.55 to 3.0 kW)
ACT201- 05 07 09 11 13 15
Size 1 (F, A or C) Size 2 (F, A or C)
Output, motor side
Recommended rated motor power P
n
kW 0.55 0.75 1.1 1.5 2.2 3.0
Rated motor current output I
n
A 3.0 4.0 5.5 7.0 9.5 12.5
Rated motor voltage output U
n
V 3 x (from 0 to mains voltage)
Overload current for 60 s I
pk
A 4.5 6.0 7.3 10.5 14.3 16.2
Overload current for 1 s I
pk
A 6.0 8.0 8.0 14.0 19.0 19.0
Switching frequency f
c
kHz From 2 to 16
Rated motor frequency f
n
Hz From 0 to 1000
Input, mains side
Nominal mains voltage U V 184 ... 264
Nominal mains frequency f Hz 45 ... 66
Nominal current 3 ph/PE I A 3.0 4.0 5.5 7.0 9.5 10.5
Nominal current 1 ph/N/PE; 2 ph/PE I A 5.4 7.2 9.5 13.2 16.5 16.5
EMI filter - - Built-in
General
Short circuit / ground fault protection - - Yes, unlimited
Mounting position - - Vertical
Protection class - - IP 20 (EN60529)
Dimensions Std. A
HxWxD
mm 190 x 60 x 175 250 x 60 x 175
Cold Plate Opt. C
HxWxD
mm 190 x 82 x 140 250 x 85 x 140
Weight (approx.) m kg 1.2 1.6
Environment
Cooling temperature T
n
°C From0to40(3K3DINIEC721-3-3)
Relative air humidity - % From 15 to 85, non-condensing
Derating P -
2,5%/Kabove40°C;Tmax=55°C;
5%/1000mabove1000minstallationaltitude;hmax=4000m
Options & accessories
Line choke - - External (depending on mains supply)
EMI filter - - Internal (EN 61800-3); external
Brake unit - - Internal brake transistor
Digital control unit - - Yes
Seitenansicht 13