Seite 1 - Solution Drive

ActiveSolution Drive

Seite 2 - Power, control

10DesignationACT201SizeFrom 0.55 to 1.1 kW / from 1.5 to 3.0 kW / from 4 to 5.5 kW / from 7.5 to 9.2 kWBasic equipment•200-240Vsingle-phaseandt

Seite 3 - About us

11DesignationACT401SizeFrom 0.55 to 1.5 kW / from 1.85 to 4.0 kW / from 5.5 to 9.2 kW / from 11 to 15 kW / from 18.5 to 30 kW / from 37 to 65 kW / fro

Seite 4 - Bonfiglioli

12•Range of voltage area: 200 - 240 V single-phase and three-phase(±10%),360-480Vthree-phase(±10%)•TNandITmainscapablethankstoadaptat

Seite 5 - Innovative solutions

13EnvironmentOperating temperature• 0°C-40°C(40°C-55°Cwithderating)Environment class• Operation3K3(EN60721-3-3)• Relativehumidity15%...

Seite 6

14ACT201 - Technical data (from 0.55 to 3.0 kW)ACT201- 05 07 09 11 13 15Size 1 (F, A or C) Size 2 (F, A or C)Output, motor sideRecommended rated motor

Seite 7 - Advanced technologies

15ACT201 - Technical data (from 4.0 to 9.2 kW)ACT201- 18 19 21 22Size 3 (- or F, A or C) Size 4 (-, A or C)Output, motor sideRecommended rated motor p

Seite 8 - Designation

16ACT401- 05 07 09 11 12 13 15Size 1 (F, A or C) Size 2 (F, A or C)Output, motor sideRecommended rated motor power PnkW 0.55 0.75 1.1 1.5 1.85 2.2 3.0

Seite 9

17ACT401- 18 19 21 22 23 25Size 2 (F, A2 or C2)Size 3 (- or F, A or C) Size 4 (-, A or C)Output, motor sideRecommended ratedmotor powerPnkW 4.0 5.5 7.

Seite 10 - Technical features

18ACT401- 27 29 31Size 5 (-, A or C)Output, motor sideRecommended rated motor power PnkW 18.5 22.0 30.0Rated motor current output InA 40.0 45.0 60.0Ra

Seite 11

19ACT401- 33 35 37 39 Size 6 (-, A)Output, motor sideRecommended rated motor power PnkW 37.0 45.0 55.0 65.0Rated motor current output InA 75.0 90.0 11

Seite 12 - Software

Power, controland green solutions

Seite 13 - General technical data

20ACT401- 43 45 47 49 Size 7 (-, A)Output, motor sideRecommended rated motor power PnkW 75.0 90.0 110.0 132.0Rated motor current output InA 150.0 180.

Seite 14 - (from 0.55 to 3.0 kW)

21ACT401-21 FA 7.5 kW motorChoosing the product size with the ACT 401/201 series is even simpler: one model for each motor power size.In addition, the

Seite 15 - (from 4.0 to 9.2 kW)

22Inverter DeratingInstallation altitudePower supply reduction (derating):5%/1000 m a.s.l.; hmax = 4000 mInstallation altitude in metres above sea lev

Seite 16

23Optional componentsThanks to the modularity of their hardware components, ACTIVE frequency inverters are easily integrated in automation application

Seite 17 - (from 4.0 to 15 kW)

24Control unit / KP500TheKP500controlunitisequippedwithaParametersCopyfunctionthatallowstheuser to upload parametric values from the inv

Seite 18 - (from 18.5 to 30 kW)

25Interface / KP-232SerialinterfaceKP232canbeusedasanalternativetocontrolunitKP500.Thisconnectionenablesparameterisation, monitoring,

Seite 19 - (from 37 to 65 kW)

26RS232 / CM-232serial communicationThe optional CM-232 communication card enables RS232 serial connection of the ACTIVE inverter to an external contr

Seite 20 - (from 75 to 132 kW)

27RS485 / CM-485serial communicationThe CM-485 communication module is designed for high speed data transmission over long distances in industrial app

Seite 21 - Inverter selection criteria

28RS485 / CM-485serial and Modbus communicationModbus communicationThe communication module CM-485 allows to use the Modbus Communication profile to be

Seite 22 - Inverter Derating

29DP / CM-PDPProfibus CommunicationProfibus DP interface fulfils fieldbus standard DIN 19245. This Profibus version, which is optimized in order to provide

Seite 23 - Optional components

About usBonfiglioli, one name for a large international groupIt was back in 1956 that Clementino Bonfiglioli established in Bologna, Italy, the company

Seite 24 - Control unit / KP500

30CANopen/ CM-CAN communicationThe CM-CAN communication option with controller area network interface, complies with ISO/DIS 11898 transmission standa

Seite 25 - Interface / KP-232

31System bus / EM-SYS moduleThe “System Bus” of Active inverters is a proprietary communication bus, based on CANopen protocol that allows fast exchan

Seite 26 - RS232 / CM-232

32Input-output module / EM-IO-01The EM-IO-01 expansion modules extends the number of the standard inputs and outputs provided on the ACT inverter for

Seite 27 - RS485 / CM-485

33Input-output module / EM-IO-02Like the previously illustrated EM-IO-01, the EM-IO-02 expansion module extends the standard inputs and outputs featur

Seite 28

34Input-output module / EM-IO-03The EM-IO-03 expansion module is another variant for the extension of I/O facilities of ACTIVE frequency inverters.•2

Seite 29 - Profibus Communication

35Input-output module / EM-IO-04The EM-IO-04 expansion module is another variant for the extension of I/O facilities of ACTIVE frequency inverters.•2

Seite 30 - CANopen/ CM-CAN

36Speed sensor module / EM-ENC-01The EM-ENC-01 expansion module extends the number of speed sensor inputs with respect to the standard terminal board

Seite 31 - System bus / EM-SYS module

37Speed sensor module / EM-ENC-02The EM-ENC-02 speed sensor module extends the standard terminal board of the inverter, providing an interface for lin

Seite 32

38Speed sensor module / EM-ENC-03The EM-ENC-03 extends the standard terminal board of the inverter, providing an interface for line driver speed senso

Seite 33

39Speed sensor module / EM-ENC-04The EM-ENC-04 speed sensor module extends the standard terminal board of the inverter, providing an interface for lin

Seite 34

Bonfigliolisolutionswindphotovoltaicindustrialmobile

Seite 35

40Speed sensor module / EM-ENC-05The EM-ENC-05 speed sensor module extends the standard terminal board of the inverter, providing an interface for lin

Seite 36 - ENCODER LineDriver

41Resolver Module / EM-RES-01The EM-RES-01 angular position transducer module extends the standard functions of the frequency inverter by providing a

Seite 37

42Resolver Module / EM-RES-02EM-RES-02 angular position transducer module extends the standard functions of the frequency inverter by providing a supp

Seite 38

43ACTIVE oscilloscope graphic presentationThe functionality and practicality of the virtual oscilloscope are identical to those of a powerful and mode

Seite 39

44110: Simple Sensorless Control111: Simple Sensorless Control with PI function115: Simple Sensorless Control with master / slave control116: Simple S

Seite 40

45Functions implemented in standard firmwareParking brake control (X60 configurations)Many drives, particularly in the mechanical engineering industry,

Seite 41 - Resolver Module / EM-RES-01

46ACT SystembusThe ACT frequency inverter systembus is an economical and powerful communication system allowing the connection of up to 64 ACT inverte

Seite 42 - Resolver Module / EM-RES-02

47Master/slave synchronisation(X16 configurations)There are several dedicated inputs for synchronisation signals (electronic gear). For master-slave co

Seite 43 - Engineering software

48MountingA wide range of mechanical accessories is available for ACT Series frequency converters, to make installation extremely easy in all sorts of

Seite 44

49Size 1Inverter Bonfiglioli Mounting DescriptionACT 201-05 … ACT 201-09ACT 401-05 … ACT 401-11MPSV1 Thru-type assemblyMNVIB1 Antivibration assemblyMDI

Seite 45

5Bonfiglioli Riduttori today is one of the top brands in the power transmission industry. The company’s success is the result of a business strategy th

Seite 46 - ACT Systembus

50Size 2Inverter Bonfiglioli Mounting DescriptionACT 201-11 … ACT 201-15ACT 401-12 … ACT 401-18MPSV2 Thru-type assemblyMNVIB2 Antivibration assemblyMDI

Seite 47 - (X16 configurations)

51Size 3Inverter Bonfiglioli Mounting DescriptionACT 201-18 … ACT 201-19ACT 401-19 … ACT 401-22MPSV3 Thru-type assemblyMNVIB3 Antivibration assemblyMNV

Seite 48 - Mounting

52Size 4Inverter Bonfiglioli Mounting DescriptionACT 201-21 … ACT 201-22ACT 401-23 … ACT 401-25MPSV4 Thru-type assemblyMNVIB4 Antivibration assemblyMNV

Seite 49

53Size 5Inverter Bonfiglioli Mounting DescriptionACT 401-27 … ACT 401-31MPSV5 Thru-type assemblyMNVIB5 Antivibration assemblyMNVIB5MPSV5Standard assemb

Seite 50

54Size 6Inverter Bonfiglioli Mounting DescriptionACT 401-33 … ACT 401-39MPSV6 Thru-type assemblyMNVIB6 Antivibration assemblyMNVIB6MPSV6Standard assemb

Seite 51

55Size 7Inverter Bonfiglioli Mounting DescriptionACT 401-43 ... ACT 401-49 MPSV7 Thru-type assemblyMPSV7Standard assemblyAABB

Seite 52

56Input filterWhy an input filter?An Input Filter is a filtration device to be installed up-line from the frequency inverter and down-line from the power

Seite 53

57Line chokeThe simplest way of reducing high harmonic components and hence reactive power is connecting a choke in series on the mains side of the in

Seite 54

58Bonfiglioli choke Dimensions Assembly Weight Connection terminala[mm]b[mm]c[mm]n2[mm]n1[mm]d[mm] [kg] [mm] [Nm] PELCVS00660 62 75 44 38 3.6 0.5 0.75-

Seite 55

59Line chokeTechnical dataBonfiglioli inverter Bonfiglioli choke Nominal current Choke Power dissipation[A] [mH] [W]ACT 201-05LCVT004 4 7.32 20ACT 201-0

Seite 57 - Line choke

60Line chokeBonfiglioli choke Dimensions Assembly Weight Connection terminala[mm]b[mm]c[mm]n2[mm]n1[mm]d[mm] [kg] [mm] [Nm] PELCVT00480 65 95 55 37 4 0

Seite 58

61EMI filtersBecause of their intrinsic characteristics, all frequency inverters often generate undesired high frequency voltages generally referred to

Seite 59

62Mains voltage 3 x 480V~ maximum +10%Nominal current 8A ... 40AFrequency 50/60 HzOperating and storage temperature  -25°C...+100°C(climat

Seite 60

63Backplate EMI filtersEMI filter A B C D G H K L1 L2[mm]FTV018B315 100 65 300 35 300 6.3 76 270FTV040B315 125 65 300 60 300 6.3 125 270Dimensions FTV00

Seite 61 - EMI filters

64Book type EMI filtersMains voltage 3 x 480 VACRated current 7 A … 130 AFrequency up to 60 HzOperating and storage temperature  -25°C...+80

Seite 62 - Backplate EMI filters

65Book type EMI filtersEMI filter A B C D E F G H I1 I2 J K1 K2[mm]FTV250A482 140 140 380 168 155 6.5 1.5 62 100 120 40 50Dimensions FTV250ADimensions F

Seite 63

66Braking resistorsWhen speed of an inverter-controlled ac motor is reduced, the motor acts as a generator, feeding back energy to the frequency inver

Seite 64 - Book type EMI filters

67Active drive combination chartThese charts show recommended combinations for each model in the Active range, and specify the corresponding duty cycl

Seite 65

Added value

Seite 66 - Braking resistors

69We want to share the valueof our work with you. The development of effective, tailored solutions for a wide range of applications is a fundamental a

Seite 67

7Advanced technologies for all industrial fields.Bonfiglioli Active frequency inverters are powerful and innovative units specifically designed to contro

Seite 68 - Added value

Branches and facilitiesOur branchesITA1Bonfiglioli Riduttori S.p.A.Gearmotor assembly plantPrecison gearbox manufacturing & assembly plantVignola,

Seite 69 - We want to share the value

71Customer satisfaction has always been one of Bonfiglioli’s key values. It is pursued around the world, and in a wide range of contexts, by a network

Seite 70 - Our production facilities

72Bonfiglioli worldwide network.Mechatronic Drives & Solutions dedicated networkBonfiglioli New Zealand88 Hastie Avenue, Mangere Bridge, Auckland202

Seite 72 - Bonfiglioli worldwide network

Bonfiglioli Riduttori S.p.A.Via Giovanni XXIII, 7/A40012 Lippo di Calderara di RenoBologna (Italy)tel: +39 051 647 3111fax: +39 051 647 3126bonfiglioli@

Seite 73

8DesignationBasic variantsACT 201 13 F AEMI filterF internal filter(blank) no internal filterConstruction styleA style with standard coolingC style

Seite 74 - Bonfiglioli Riduttori S.p.A

9Basic variantsACT 401 15 F AEMI filterF internal filter(blank) no internal filterConstruction styleA style with standard coolingC style with cold-